Cuprora/Technology

Match the process to the function.

SLA, aluminium, POM, inserts, pogo probes — each of these words only makes sense once you know what carries the load, what defines the geometry and what has to be replaceable.

ABC DE RAMADOCISKPŁYTA PINOWA NESTINTERFEJS SEKCJA A–A / FIXTURE FCT SKOK DOCISKU

LAYERS

How a fixture is built

From the bottom: an aluminium frame, a base plate, press guidance, the probe plate and a nest that locates the board. Every layer has a different job — which is why we don't make everything from one material.

  • 01 / FRAME

    Aluminium profile, carries the clamping load.

  • 02 / BASE PLATE

    Aluminium, the reference plane.

  • 03 / PROBE PLATE

    Probe plate, guided on posts.

  • 04 / NEST

    POM or printed, geometry for a specific board.

  • 05 / INTERFACE

    Translator or harness to the tester.

02 / MATERIALS

SLA or CNC? The answer depends on the part.

We don't claim that printing replaces machining. We claim that most fixture geometry does not need CNC — and the parts that do, we source.

Process comparison — fixture application, not a general technology ranking
CriterionSLA printingCNC aluminium
Cost of the first partLow — no programming or fixturingHigh — program, setup, workholding
Geometry changeNew file, another printNew program and new workholding
Tolerance±0.15 mm as printed; critical faces machined after±0.05 mm; hole position ±0.02 mm
StiffnessE ≈ 10 GPa — cannot carry probe forceE ≈ 69 GPa — carries 1.5 kN
Threads and insertsEpoxy-bonded or press-fit; heat-set does not work in a thermosetThread cut into the material
Thermal stabilityHDT 82 °C; CTE 30–80 ppm/KContinuous use to ~150 °C; CTE 23.6 ppm/K
When we choose itNest, housing, pockets, guides, prototypeFrame, probe plate, reference planes

CALCULATION

Why the probe plate is not resin

Let's do the maths: 500 probes × 3 N is 1.5 kN. A 300 × 200 × 10 mm plate supported at its edges deflects by about 3.2 mm in Rigid 10K resin (E ≈ 10 GPa) and about 0.46 mm in 6061 aluminium (E ≈ 69 GPa). With supports every 100 mm the ratio is still an order of magnitude. That is why the probe plate is metal or FR4 on a metal support — and printing handles the nest, pockets and housing.

Simplified beam model, uniformly distributed load. This is not an FEA result — it is an order of magnitude that shows where resin stops working.

δ = 5qL⁴ / 384EI 3.2 mmSLA · E 10 GPa 0.46 mmAl 6061 · E 69 GPa 500 probes × 3 N · 300×200×10 mm plate
03 / MATERIALS

Materials we use

SLA / DLP resin

Nest, pockets, housings, guides. Rigid 10K or equivalent: E ≈ 10 GPa, HDT 82 °C. Never used for plates that carry probe force.

Aluminium 6060 / 6082

Frame, probe plate, reference planes. Cut and milled by a supplier, inspected on receipt.

FR4 / G10

Probe plates and insulators. E ≈ 20–24 GPa, CTE 12–16 ppm/K — more stable than POM or resin.

Bent sheet metal

Enclosures, panels, guards. Bending and punching to order.

POM / PTFE

Bushings, sliding guides, low-friction parts. With creep and CTE of 110–120 ppm/K in mind.

Pogo probes

Standard, high-current, Kelvin, RF — selected for current, pitch, force and life.

Inserts and fasteners

Brass inserts bonded with 2K epoxy or press-fit; class 8.8 screws; ESD components.

04 / PROBES

Pogo probes: four parameters that decide

The probe is not an accessory. It decides current, resistance and whether the fixture survives a year on the line.

01

Current

Standard 1–3 A; Ingun GKS-100 is rated 5 A at 20 mΩ, HSS-150 50 A at <10 mΩ. For higher currents we parallel probes or use a high-current series.

02

Pitch

1.27 mm, 1.9 mm, 2.0 mm, 2.54 mm. The finer the pitch, the harder the access and the more expensive the probe — GKS-050 is already a 1.27 mm probe.

03

Life

Catalogue figures run from 100k to over a million cycles under laboratory conditions. In production, spring, cleaning and guidance matter more than the datasheet.

04

Resistance

Typically 20–50 mΩ. For milliohm measurements we use Kelvin (4-wire) probes and a separate wire pair.

A probe specification, not “high-quality probes”

Every quote includes a probe specification: manufacturer, type, current, resistance, spring force, pitch, stated life and price. The customer sees what they pay for — and can buy a replacement themselves.

Ingun GKS-1005 A · 20 mΩ · 2,54 mm
Ingun HSS-15050 A · <10 mΩ · 5,08 mm
Feinmetall F077023 A · 25 mΩ · 195 cN

05 / ACCEPTANCE

An acceptance protocol, not an assurance

The first article does not leave the workshop without measurement. The test scope depends on the fixture, but the list is fixed before the build — and always ends with a report.

  • Continuity and isolation — 100% of probes, report with values
  • Clamping force and planarity — measured with a gauge, limit in the documentation
  • Position repeatability — CMM/vision, 30 samples, ±0.05 mm CNC / ±0.15 mm SLA
  • GR&R — on request, for critical measurements
  • 1,000-cycle test — on the first article when in scope
  • Package: STEP, pin map, BOM, instructions, service card

06 / STANDARDS

Standards — without certificates we don't hold

Assembly and harnesses follow IPC-A-610 class 2 and IPC/WHMA-A-620 as a quality reference, not as certification. Interface boards are designed to IPC-2221/2222. IPC-9252 applies to bare boards — we do not use it as evidence for assembled PCBA. We are implementing an ESD programme to ANSI/ESD S20.20. We do not hold ISO 9001 and do not claim it.

EVIDENCE POLICY

Every number on this site has a source: a measurement, a manufacturer document, or an explicit “to be validated”. We don't use “98%”, “120+” or “4.9” without data. If we haven't measured it, we say so.

Cuprora · Warsaw · 2026

See what's in the package

Gerber X2, ODB++, IPC-2581, STEP and a test point list. We reply within 24 business hours.

Send your files Quote within 24 business hours